Geen bewerkingssamenvatting
Geen bewerkingssamenvatting
Regel 1: Regel 1:
==== Summary ====
====Facts====
*Country: Netherlands
*Type of provider: Campsite
*Focus:
**Reduce: Efficient use of energy
**Recover: Heat recovery from shower water is used
 
====Summary====
A sustainable sanitary building has been installed where 26 camping guests can shower at the same time. Two AT-TEC air / water heat pumps have been installed and heat recovery from shower water is used. The heat pumps are placed in cased and heat the 1500 liters of water in the buffer vessel. This water is also heated by the seven flat-bile solar collectors. The following technical installations were used: 2 monoblock heat pumps 12-34 kW in cascade, 1500 liter buffer vessel with hygiene spiral for hot tap water preparation and a heat exchanger, 7 flat glass collectors, 2 HLTWS tap water boilers of 1000 liters with heat exchangers and 8-pipe multivert with pump unit.
A sustainable sanitary building has been installed where 26 camping guests can shower at the same time. Two AT-TEC air / water heat pumps have been installed and heat recovery from shower water is used. The heat pumps are placed in cased and heat the 1500 liters of water in the buffer vessel. This water is also heated by the seven flat-bile solar collectors. The following technical installations were used: 2 monoblock heat pumps 12-34 kW in cascade, 1500 liter buffer vessel with hygiene spiral for hot tap water preparation and a heat exchanger, 7 flat glass collectors, 2 HLTWS tap water boilers of 1000 liters with heat exchangers and 8-pipe multivert with pump unit.
 
====Involved parties====
==== Strategies ====
''Reduce''
 
Efficient use of energy
 
''Recover''
 
Heat recovery from shower water is used
 
==== Involved parties ====
Gelders Service bedrijf, RCN De Jagerstee and Rentema Adviesbureau Installatietechniek
Gelders Service bedrijf, RCN De Jagerstee and Rentema Adviesbureau Installatietechniek
====More information====
Do you want to know more about this project? Please visit their website (Dutch): https://www.technea.nl/project/duurzaam-sanitair-gebouw-op-vakantiepark-rcn-de-jagerstee/


==== See more? ====
Do you want to know more about this project? Please visit their website: https://www.technea.nl/project/duurzaam-sanitair-gebouw-op-vakantiepark-rcn-de-jagerstee/
{{Project FACET Practice config}}
{{Project FACET Practice config}}
{{Project
{{Project

Versie van 21 okt 2021 17:04

Facts

  • Country: Netherlands
  • Type of provider: Campsite
  • Focus:
    • Reduce: Efficient use of energy
    • Recover: Heat recovery from shower water is used

Summary

A sustainable sanitary building has been installed where 26 camping guests can shower at the same time. Two AT-TEC air / water heat pumps have been installed and heat recovery from shower water is used. The heat pumps are placed in cased and heat the 1500 liters of water in the buffer vessel. This water is also heated by the seven flat-bile solar collectors. The following technical installations were used: 2 monoblock heat pumps 12-34 kW in cascade, 1500 liter buffer vessel with hygiene spiral for hot tap water preparation and a heat exchanger, 7 flat glass collectors, 2 HLTWS tap water boilers of 1000 liters with heat exchangers and 8-pipe multivert with pump unit.

Involved parties

Gelders Service bedrijf, RCN De Jagerstee and Rentema Adviesbureau Installatietechniek

More information

Do you want to know more about this project? Please visit their website (Dutch): https://www.technea.nl/project/duurzaam-sanitair-gebouw-op-vakantiepark-rcn-de-jagerstee/